Type 8605 Digital control electronics for solenoid valves Digitale Ansteuerelektronik für Magnetventile Régulateur électronique numérique pour électrovanne Quickstart...
THE QUICKSTART Table of contents The Quickstart contains the most important information and notes The Quickstart ................. 2 regarding the use of the device. Keep the Quickstart ready to hand at Intended use ................... 3 the operation site. Important safety information. Basic safety instructions ..............
INTENDED USE NOTE The digital control electronics for solenoid valves Type 8605 are Warns of damage to property. designed to control Bürkert valves. ▶ Use the device only as intended. Non-authorised use of the Important tips and recommendations. device may be dangerous to people, nearby equipment and the environment.
BASIC SAFETY INSTRUCTIONS WARNING These safety instructions do not make allowance for any contingencies Risk of injury due to pressure drop. and events which may arise during assembly, operation and maintenance. ▶ Prevent a pressure drop. The operator is responsible for observing the location-specific safety ▶...
Fig. 1: Type 8605, control electronics with connector diagram A PRODUCT DESCRIPTION During operation of the control electronics Type 8605 in the cable plug variant, the operating state is indicated by 2 LEDs. Intended application area The following options are available to the user: Type 8605 is designed for permanent use in industrial environments, in •...
TECHNICAL DATA Technical data of the cable plug Conformity Degree of protection IP65 (DIN EN 60529) The device conforms to the EU directives according to the EU Declaration Materials Polyamide / PC of Conformity (if applicable). Dimensions (LxWxH) 70 x 32 x 42.5 mm 5.2 Standards The applied standards, which are used to demonstrate conformity with the directives, are listed in the EU type test certificate and/or the EU...
ASSEMBLY Electrical connection Type 8605 with cable plug is connected to the power via a 4-pole ter- DANGER minal strip in the device. Risk of injury due to high pressure and discharge of medium. Cable diameter 6...8 mm ▶ Before working on the device or system, switch off the pressure.
Page 8
6.2 Mounting the control electronics Shield CAN_H CAN_L 12...24 V Fig. 3: Plug-in connector connection, digital Seal Screw M3 Cable plug Seal Cover Fig. 5: Mounting the control electronics on the valve When screwing the cable plug to the valve, ensure that the seal Fig.
LED NAMUR: Device status according to CLEANING NAMUR NE107 Clean the control electronics Type 8605 with standard cleaning agents. Fig. 6: LED display of the control electronics without an operating unit Do not use any alkaline cleaners, as these will have damaging effects on the materials used.
DISASSEMBLY TRANSPORTATION, STORAGE, DISPOSAL DANGER NOTE! Risk of injury due to high pressure and discharge of medium. Damage in transit due to inadequately protected devices. ▶ Before working on the device or system, switch off the pressure. ▶ During transportation protect the device against moisture and dirt Vent or drain the lines.