Sealite SLC500 Installation & Service Manual

Sealite SLC500 Installation & Service Manual

Solar marine lantern
Hide thumbs Also See for SLC500:

Advertisement

Quick Links

SLC500 & SLC600
Solar Marine Lanterns
Installation & Service Manual
Version 4.0

Advertisement

Table of Contents
loading

Summary of Contents for Sealite SLC500

  • Page 1 SLC500 & SLC600 Solar Marine Lanterns Installation & Service Manual Version 4.0...
  • Page 3: Table Of Contents

    Maintenance and Servicing ..............Page 24 Trouble Shooting ................Page 25 Sealite Lantern Warranty ..............Page 27 Version No. Description Date Approved Update Manual August 2010 K. Paton Update Spec Table & Remove SLC400 May 2012 J. Dore Latest products and information available at www.sealite.com...
  • Page 4: Introduction

    As a commitment to producing the highest quality products for our customers, Sealite has been independently certified as complying with the requirements of ISO9001:2008 quality management system. Sealite lanterns comply with requirements of the US Coast Guard in 33 CFR part 66 for Private Aids To Navigation. By taking a few moments to browse through this booklet, you will become familiar with the versatility of your lantern, and be able to maximise its operating function.
  • Page 5: Slc500 Model

    SLC500 & SLC600 Solar Marine Lanterns SLC500 Model The SLC500 is a completely self-contained 5-7nm+ Solar LED Marine Lantern designed for a range of low-maintenance applications. The light boasts a large internal battery compartment, a multiple tiered SL125 light-head, and 4 premium-grade 10watt solar modules mounted to collect sunlight at all angles.
  • Page 6: Specifications

    Waterproof IP68 light-head Intellectual Property Patents US Pat. No. 6,667,582. AU Pat. No. 778,918 Trademarks SEALITE® is a registered trademark of Sealite Pty Ltd Warranty * 3 years Options Available • 200mm OD mounting plate • GPS Synchronisation • RF Synchronisation •...
  • Page 7 SLC500 & SLC600 Solar Marine Lanterns Figure 1. SLC500 Latest products and information available at www.sealite.com...
  • Page 8: Slc500 Optional Configurations

    GSM Monitoring & Control (SLC500-GSM) The SLC500 may also be fitted with GSM remote monitoring and control capabilities - enabling users to access real-time diagnostics data and change lantern settings via cell-phone or PC interface. Radio Control (SLC500-RC) Radio control may be fitted to SLC500 model enabling users to remotely modify the setup of their lantern via handheld radio controller (SL-RC-2.4). For example, the operator can remotely change between different coloured LED banks (to change the colour of the light), turn their lights ON and OFF, or change the flash setting. Perfect for remote traffic control and to designate an area of activity. Latest products and information available at www.sealite.com...
  • Page 9: Slc600 Model

    UV-stabilised, virgin modules, ensuring polyethylene body maximum light collection to charge the battery Internal 100Ah battery High visibility 7-stage powder-coated IALA colours for aluminium base with daytime recognition handles for ease of installation Latest products and information available at www.sealite.com...
  • Page 10 Waterproof IP68 light-head Intellectual Property Patents US Pat. No. 6,667,582. AU Pat. No. 778,918 Trademarks SEALITE® is a registered trademark of Sealite Pty Ltd Warranty * 3 years Options Available • 200mm OD mounting plate • GPS Synchronisation • RF Synchronisation •...
  • Page 11 SLC500 & SLC600 Solar Marine Lanterns Figure 2. SLC600 Latest products and information available at www.sealite.com...
  • Page 12: Slc500 Optional Configurations

    GSM Monitoring & Control (SLC600-GSM) The SLC600 may also be fitted with GSM remote monitoring and control capabilities - enabling users to access real-time diagnostics data and change lantern settings via cell-phone or PC interface. Radio Control (SLC600-RC) Radio control may be fitted to SLC600 model enabling users to remotely modify the setup of their lantern via handheld radio controller (SL-RC-2.4). For example, the operator can remotely change between different coloured LED banks (to change the colour of the light), turn their lights ON and OFF, or change the flash setting. Perfect for remote traffic control and to designate an area of activity. Latest products and information available at www.sealite.com...
  • Page 13: Installation

    Care must be taken to observe the polarity of each wire before they are connected. To ensure waterproofing of the unit, make sure that no wires are protruding and that there is an even seal. Latest products and information available at www.sealite.com...
  • Page 14 Selecting a Flash Code- Rotary Switches A and B All lanterns have 2 rotary switches marked A and B on the flasher unit. Turning the small arrows to the appropriate number or letter will set the code. The unit may take up to one minute to activate a new flash code. A comprehensive list of available flash codes is listed on in the ‘Flash Codes’ section of this manual. Example: SWITCH FLASH CODE FL 3 S Latest products and information available at www.sealite.com...
  • Page 15: Rf Synchronisation (Comm-Sync) Option

    Synchronisation is achieved via short-range RF communication between lanterns, and relies on line-of-sight operation. Setup To enable flash synchronisation of independent RF Comm-Sync lanterns, set lanterns to the same flash characteristic (see “Selecting a Flash Code” section of this manual). IMPORTANT: only lights set to the exact same flash pattern/code will flash in synchronisation. Latest products and information available at www.sealite.com...
  • Page 16: Gps Synchronisation Option

    • Checks for valid time data and is turned on after a delay based on the current time and the length of the selected flash code; • If valid time data is not detected the light will turn on after approximately 10 seconds. This light will not be synchronised. • If the light turns on unsynchronised it will continually check for valid time data. Once valid data is found the light will automatically synchronise. Setup To enable flash synchronisation of independent RF Comm-Sync lanterns, set lanterns to the same flash characteristic (see “Selecting a Flash Code” section of this manual). IMPORTANT: only lights set to the exact same flash pattern/code will flash in synchronisation. Latest products and information available at www.sealite.com...
  • Page 17: Lantern Status

    Check regulator if Voltage (>15.3v) persists. Internal ambient temperature is High internal Flashing ON/ Flashing ON/ >75°C. Selected light intensity ambient OFF 9 times per OFF 1 time per is dropped by 25%. Will temperature second second resume normal operation when (>75°C) temperature <75°C. Latest products and information available at www.sealite.com...
  • Page 18 Flashing ON/ OFF very OFF very quick Normal GPS software running. quick constant constant faint C. Flashes in Flashes in sequence with sequence with OFF/ON GPS software not operational. red LED yellow LED Latest products and information available at www.sealite.com...
  • Page 19: Flash Codes

    SLC500 & SLC600 Solar Marine Lanterns Flash Codes Sealite Lanterns may be set to any of 256 IALA recommended flash settings which are user-adjustable onsite without the need for external devices. SEALITE® code reference is listed by number of flashes For the latest version of this document visit www.sealite.com or email info@sealite.com Symbols Flash followed by number Eg. FL 1 S, one flash every second Fixed...
  • Page 20 FL 5 S FL 15 S 14.0 FL 5 S LFL 15 S 11.0 FL 5 S OC 15 S FL 5 S LFL 20 S 18.0 FL 5 S FL 26 S 25.0 Latest products and information available at www.sealite.com.au...
  • Page 21 FL (2) 10 S FL (2) 10 S FL (2) 10 S FL (2) 10 S FL (2) 10 S FL (2) 10 S FL (2) 10 S FL (2) 10 S Q (2) 10 S FL (2) 12 S 10.2 FL (2) 12 S 10.0 FL (2) 12 S FL (2) 15 S 11.0 FL (2) 15 S 11.0 Q (2) 15 S 13.8 FL (2) 20 S 15.0 FL (2) 25 S 22.0 SWITCH FLASH CODE Q (3) 5 S VQ (3) 5 S VQ (3) 5 S VQ (3) 5 S FL (3) 6 S FL (2+1) 6 S Latest products and information available at www.sealite.com...
  • Page 22 FL (3) 20 S 15.0 SWITCH FLASH CODE VQ (4) 4 S Q (4) 6 S Q (4) 6 S FL (4) 10 S FL (4) 10 S Q (4) 10 S FL (4) 12 S FL (4) 12 S FL (4) 12 S FL (4) 12 S Q (4) 12 S FL (4) 15 S FL (4) 15 S FL (4) 15 S 10.5 FL (4) 16 S FL (4) 20 S FL (4) 20 S 13.5 FL (4) 20 S 10.5 FL (4) 20 S Q (4) 20 S 16.5 Q (4) 28 S 24.5 FL (4) 30 S 26.5 Latest products and information available at www.sealite.com...
  • Page 23 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 4.8 SWITCH FLASH CODE MORSE CODE ( ) INDICATES LETTER MO (A) 6 S MO (A) 8 S MO (A) 8 S MO (U) 10 S MO (U) 10 S MO (U) 10 S MO (A) 10 S MO (D) 10 S MO (A) 15 S 11.0 MO (U) 15 S 11.8 MO (U) 15 S 10.7 MO (U) 15 S 10.1 MO (B) 15 S 10.5 Latest products and information available at www.sealite.com...
  • Page 24: Maintenance And Servicing

    Maintenance and Servicing Designed to be virtually maintenance-free, the SLC500 and SLC600 require minimal attention, though the following maintenance and servicing information is provided to help ensure the life of your Sealite product. 1. Cleaning Lens- occasional cleaning of the light lens may be required. Using a cloth and warm soapy water, wipe off any foreign matter before rinsing the lens with fresh water.
  • Page 25: Trouble Shooting

    • Turn rotary switches several times to ensure contacts are clear. Lantern will not operate for the • Expose lantern to direct sunlight and monitor operation for several days. entire night. Sealite products typically require 3.0 hours of direct sunlight per day to retain full autonomy. From a discharged state, the lantern may require several days of operational conditions to ‘cycle’ up to full autonomy. • Reducing the light output intensity or duty cycle (flash code) will reduce current draw on the battery.
  • Page 26 Sealite within 30 days of your purchase. 2. Online Registration - please complete the Online Registration Form at; www.sealite.com Sealite Pty Ltd will repair or replace your LED light in the event of electronic failure for a period of up to three years from the date of purchase. The unit must be returned to Sealite freight prepaid.
  • Page 27: Sealite Lantern Warranty

    SLC500 & SLC600 Solar Marine Lanterns 3. The customer must give Sealite Pty Ltd notice of any defect with the product within 30 days of the customer becoming aware of the defect. 4. Rechargeable batteries have a limited number of charge cycles and may eventually need to be replaced.
  • Page 28 & Control Systems Bridge & Barge Lights Marine Buoys (up to 3mt in diameter) Area Lighting Mooring Systems & Accessories Head Office Sealite Pty Ltd 11 Industrial Drive Somerville, Vic 3912 Australia Tel: +61 3 5977 6128 Fax: +61 3 5977 6124 Email: info@sealite.com Internet: www.sealite.com Latest products and information available at www.sealite.com...

This manual is also suitable for:

Slc600

Table of Contents